Note: The rated current and coil
resistance are measured at a coil temperature at 20°C
with tolerances of +15%, –20% for rated current +10% for
rated coil resistance.
CONTACT RATINGS
Item Load Type
Resistive load (p.f. = 1)
Inductive Load (p.f. = 0.4, L/R = 7msec)
Material
Ag CdO, Two Type: 5A
Rated load
120VAC 6A 30VDC 6A
120VAC 3.0A 30VDC 3.0A
Carry current
6A
Max. operating voltage
250VAC, 125VDC
Max. operating current
6A
3.0A
Max. switching capacity
600A, 120W
300VA, 60W
Minimum permissible load (reference
value)
5VDC, 100mA
CHARACTERISTICS
Contact resistance
50m Ohms max.
Operate time
10 msec. max.
Release time
5 msec. max.
Operating Frequency
Mechanically:
18,000 operations/hour
Electrically:
1,800 operations/hour (under rated load)
Insulation resistance
100M Ohms min. (at 500VDC)
Dielectric strength
1,500 VAC, 50/60 Hz for 1 minute between coil and
contact, dissimilar pole 750 VAC, 50/60 Hz for 1
minute between non-continuous contacts of same
pole